    Description

    Please note:
    This meter is made by FLUKE manufacturer in China. Now China Fluke manufactures don't provide printed English user manual and CD.
    The outer packing may be in Chinese.
    And there is no battery comes with .
    Feature:
    LED backlight
    (new)
    Larger screen: 1.5 times of F1
    5
    B's
    (new)
    Faster response time than F1
    5
    B
    (new)
    Date Hold Function
    Both Auto range and Manual range Selectable
    Over range protection for all ranges
    Polarity Indication: Indicates negative polarity
    Overflow Indication
    Sleep Mode /Auto Power off / Low Battery Indication
    Continuity Test with Alert
    Diode Test
    Power Supply: 2 x AA 1.5V Battery
    (Excluding)
    General Specifications:
    Maximum Voltage between any Terminal and Earth Ground: 1000 V
    Display(LCD).......................................................4000 counts,updates 3/sec
    Battery Type..........................................................2 AA,NEDA 15A, IEC LR6
    (Excluding)
    Battery life.............................................................500 hours minimum(50 hours in LED Test mode without load. The hours with load depends on the type of LED under test)
    Temperature
    Operating..............................................................0 deg to 40 deg
    Storage.................................................................-30 deg to 60 deg
    Relative Humidity
    Operating Humidity.............................................Non-condensing≤90%at 10deg to 30deg;≤75% at 30deg to 40deg
    Operating Humidity,40MC Range....................≤80% at 10deg to 30deg;≤70% at 30deg to 40deg
    Altitude
    Operating..............................................................2000m
    Storage.................................................................12.000m
    Temperature Coefficient....................................0.1×(specified accuracy)/deg(<18deg or > 28deg)
    Fuse protection for current inputs....................440 mA,1000 V Fast Fuse, Fluck specified part only.
    11A,1000v Fast Fuse, Fluke specified part only.
    Size(H×W×L)........................................................183×91×49.5(mm)
    Weight....................................................................455g
    IP Rating................................................................IP 40
    Safety.....................................................................IEC 61010-1, IEC61010-2-030 600V CAT Ⅲ,1000V CATⅡ,Pollution Degree 2
    Electromagnetic Environment..........................IEC 61326-1:Portable
    E
    lectromagnetic Compatibility.........................Applies to use in Korea only
    Class A Equipment(Industrial Broadcasting and Communication Equipment)
    ACCURACY SPECIFICATION:
    Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy
    specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
    Function
    Range
    Resolution
    Accuracy
    Model 15B+
    Model 17B+
    AC Volts (40 to 500 Hz)
    400.0 mV 1
    0.1 mV
    3.0 % + 3
    3.0 % + 3
    4.00 V
    40.00 V
    400.00 V
    1000.00 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    1.0 % + 3
    1.0 % + 3
    DC Millivolts M
    400.0 mV
    0.1 mV
    1.0 % + 10
    1.0 % + 10
    DC Volts V
    4.000 V
    40.00 V
    400.0 V
    1000 V
    0.001 V
    0.01 V
    0.1 V
    1 V
    0.5 % + 3
    0.5 % + 3
    Diode Test
    2.000 V
    0.001 V
    10 %
    Temperature
    50 °C to 400 °C
    0 °C to 50 °C
    -55 °C to 0 °C
    0.1 °C
    NA
    2 % + 1 °C
    ± 2 °C
    9 % + 2 °C
    Resistance (Ohms)
    400.0 Ω
    4.000 kΩ
    40.00 kΩ
    400.0 kΩ
    4.000 MΩ
    40.00 MΩ
    0.1 Ω
    0.001 kΩ
    0.01 kΩ
    0.1 kΩ
    0.001 MΩ
    0.01 MΩ
    0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3
    0.5 % + 3
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    0.5 % + 2
    1.5 % + 3
    Capacitance
    50.00 nF
    500.0 nF
    5.000 µF
    50.00 µF
    100.0 µF
    1000.0µF
    0.01 nF
    0.1 nF
    0.001 µF
    0.01 µF
    0.1 µF
    1µF
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    2 % + 5
    2 % + 5
    5 % + 5
    5 % + 5
    5 % + 5
    Frequency Hz (10 Hz -100 kHz)
    50.00 Hz
    500.0 Hz
    5.000 kHz
    50.00 kHz
    100.0 kHz
    0.01 Hz
    0.1 Hz
    0.001 kHz
    0.01 kHz
    0.1 kHz
    NA
    0.1 % + 3
    Duty Cycle
    0.1 % to 99.9 %
    0.1%
    NA
    1% typical
    Function
    Range
    Resolution
    Accuracy
    Model 15B+
    Model 17B+
    AC Current (40 to 200 Hz)
    400.0 µA
    0.1 µA
    1.5 % + 3
    1.5 % + 3
    4000 µA
    1 µA
    AC Current (40 to 200 Hz)
    40.00 mA
    0.01 mA
    1.5 % + 3
    1.5 % + 3
    400.0 mA
    0.1 mA
    AC Current (40 to 200 Hz)
    4.000 A 10.00 A
    0.001 A 0.01 A
    1.5 % + 3
    1.5 % + 3
    DC Current
    400.0 µA
    0.1 µA
    1.5 % + 3
    1.5 % + 3
    4000 µA
    1 µA
    DC Current
    40.00 mA
    0.01 mA
    1.5 % + 3
    1.5 % + 3
    400.0 mA
    0.1 mA
    DC Current
    4.000 A
    0.001 A
    1.5 % + 3
    1.5 % + 3
    10.00 A
    0.01 A
    Function
    Overload Protection
    Input Impedance (Nominal)
    Common Mode Rejection Ratio
    Normal Mode Rejection
    AC Volts V
    1000 V
    >10 MΩ <100 pF
    >60 dB at dc, 50 or 60 Hz
    _
    DC Volts V
    1000 V
    >10 MΩ <100 pF
    >100 dB at dc, 50 or 60 Hz
    >60 dB at 50 or 60 Hz
    STANDARD ACCESSORIES
    1. A Pair of Original
    Test leads TL75
    2. FLUKE F15B+ meter
    3. Original User Manual
    Note:
    This meter is made by FLUKE manufacturer in China. Now China Fluke manufacturers don't provide printed English user manual. The meter comes with an English user manual printed by us.
    You can also download English user manual online:
    http://assets.fluke.com/manuals/151718__umeng0000.pdf
    Notice:
    The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support!
    Shipping:
    We will ship all items within 1-3 working days upon receipt of payment,our goal is: ship it as fast as we can.
    Standard Shipping: To USA,UK and Australia by ePacket,need 7-14 working days.
    Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.But sometimes int'l delivery is highly depended on the courier company and local customs/duties.
    Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility.
    Warranty&Reture Policy:
    We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you
    A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions
    manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
    30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty requirements.